+234(0)7098809476
The IoT-based smart indoor air quality monitoring system designed to identify and normalise gaseous contaminants in confined spaces is presented in this work, along with its experimental evaluation. To measure pollution levels in real time, the system combines an ESP32 microprocessor with environmental and gas sensors from the MQ series. Pollutant discharge was carried out at different distances (0.5–2.0 m) from the sensor in a controlled indoor laboratory setting (10 ft × 12 ft). ANOVA and Tukey tests were used in the statistical analysis to assess the significance of the observed differences. The measured concentrations of acetone ranged from 47.6 to 54.7 ppm, while the mean detection time varied from 4.1s at 0.5 m to 12.0s at 2.0m. Over distances, CO concentrations ranged from 25.4 to 37.1ppm, with slower response times of 6.1 to 18.4s. At low concentrations, ammonia (NH3) showed comparatively quick detection, with response times ranging from 4.7 to 15.0 s at concentrations between 7.7 and 9.5 ppm. The slowest reaction was displayed by toluene, which ranged from 6.3 to 18.6s and had concentrations between 20.6 and 29.4 ppm. Both pollutant type and sensor distance exhibited statistically significant effects on detection time (p < 0.001), with a significant interaction effect (p = 0.004), according to the results of a two-way ANOVA. The results emphasize how crucial it is to site sensors strategically and take pollutants into account when monitoring indoor air quality