+234(0)7098809476
The high torque ripple in Flux-Switching Wound-Field Machines (FSWFM) limits their adoption for Electric Vehicle traction. This paper presents a finite element-based parametric analysis of a 1.5 kW, 24-stator-slot, 10-rotor-pole FSWFM. The field current and rotor pole embrace were varied simultaneously over predefined ranges using a linear-step parametric sweep. The effects of the two variables on average electromagnetic torque, torque ripple, efficiency, and power factor were assessed. The preferred design, obtained at a field current of 2.175 A and rotor pole embrace of 0.40, reduced torque ripple from 16.67% to 6.62%, corresponding to a 60% reduction. Average electromagnetic torque increased from 10.35 Nm to 15.18 Nm, while efficiency increased from 93.22% to 95.24%. The results show that combined variation of electrical excitation and rotor geometry can significantly improve torque smoothness and electromagnetic performance without introducing permanent magnets or additional machine complexity. Further work should include thermal, vibroacoustic, and experimental validation